General Authority of Roads & Bridges, Ministry of Transportation |
1998 |
Both systems were completely designed, engineered and executed by ASET to operate all
loads in both EL-Een EL-Sokna toll station, and Suez Piscol Balance.The system was designed to maintain the maximum possible reliability by a priority method,
which shut down some of the least important loads to keep main loads operating, when battery capacity reaches to a preset value.
In addition, when battery capacity falls to a preset value, the system would automatically operate a diesel generator that will charge batteries again through an AC battery Charger.
The system can be also switched to a manual mode to operate loads through the diesel generator directly, if the solar system fails to operate due to any reasons.
The system is completely controlled via telephone modem, and all parameters of the system are recorded for analysis.
|
| |
EL - Een EL - Sokhna Site |
Solar Modules: (316) SP75 Siemens Solar Modules
with a total Capacity of 23,700 WpBattery :(24) ABSOLYTE IIP 1-100A87 GNB
Technologies, with a total Capacity of
5585 Ah, C100, 48VDC
Controller :2) SPS48D200N Siemens Showa, with a
total capacity of 400A, 48 VDC
Inverters :ASP Pure Sine Wave Inverters with a
total capacity of 11.5 KVA
Charger :70 Amp AC Charger by Thyron Data Logger :MODAS 1632 by NES Germany
|
Solar Modules: (156) SP75 Siemens Solar Modules with a total Capacity of 11,700 Wp
Battery :(24) ABSOLYTE IIP 1-100A87 GNB Technologies, with a total Capacity of 5585 Ah,
C100, 48 VDC
Controller : (2) SPS48D200N Siemens Showa, with a total capacity of 400A, 48 VDC
Inverters : ASP Pure Sine Wave Inverters with a total capacity of 8 KVA AC Charger : 60 Amp AC Charger by Thyron
Data Logger : MODAS 1632 by NES Germany |
|
|